• Call us: +91 93500-21472



EXTRA SAFE WIRES

DESCRIPTION:

ZHFFR (ZERO Halogen Free Flame Retardant) insulation 105°C | Non-Toxic & Non-Corrosive | Does not propagate flame & fire

• REACH, ROHS, CE and CPR Compliant
• Anti-Rodent, Anti-Termite
• 100% Electrolytic Copper
• More than 101% Conductivity

Application
These cables are ideal for domestic applications, conduit wiring and fixed, protected installations. Apart from residential and commercial properties, these cables are best suited for Auditoriums, Hospitals, Hotels, Schools, Stadiums and all constructions for Public usage. These cables are ideal for use in environments where high-performance, reliability and safety is a norm. also Suitable for use in conduit and for fixed, protected installation particularly suitable for wiring in fire and explosion prone areas, chemical factories, densely wired areas, public buildings, schools, hospitals, commercial complexes, theatres, etc.

Technical Data
Approvals: IS 17048 marked, FIA/TAC
Cable Code: XZ
Voltage Grade: Up to and including 1100V
Conductor: Strands of electrolytic annealed plain copper are multi-drawn for uniformity of resistance, dimension and flexibility.
Insulation: EVA BASE POLYMER
Colours: Green, Black, Red, Yellow, Blue, White
Marking: The cables are marked 'EXTRA SAFE'
Packing: 90 mtrs. Coils packed in protective cartons.

Properties
• Temperature range: -15°C to +105°C
• Max. Short circuit temperature rating: 250°C
• the insulation does not burn readily.
• It does not melt and drip
• Smoke is negligible, transparent, non-toxic
• the victims trapped in fire do not suffocate and this facilitate firefighting operations.
• The cable has extended service life against the conventionally used cables.
• The cable is also ozone resistant
• Self-extinguishing and flame retardant according to IS 10810 P - 61

Cable Design Parameters
Kindly complete the part numbers for these cables by adding the suffix (in place of 'xx') for the colour required
01 - Green, 02 - Black, 03 - Red, 04 - Blue, 05 - Yellow, 06 - White


PRODUCT DETAILS:

Nominal Cross Sectional Area (Sq. mm)

Nominal Insulation Thickness (mm)

Number *Nominal Dia. of Strands

Approx. Overall Diameter (mm)

Max. DC Conductor Resistance at 20�C (Ω/km)

Current Rating (Amps)

Casing

Concealed

0.75*

0.6

11/0.3

2.4

26.00

10

9

1.0*

0.7

14/0.3

2.7

19.50

16

15

1.5*

0.7

22/0.3

3.0

13.30

21

19

2.5*

0.8

36/0.3

3.7

7.98

34

27

4.0**

0.8

56/0.3

4.1

4.95

38

31

6.0**

0.8

84/0.3

4.6

3.30

50

41

 

* As per conductor class 2 of IS 8130
* As per conductor class 5 of IS 8130

 

 




 

Test Parameters for Assessment of Halogen:

Test

Test Method

Values

pH

IS 17048

≥ 4.3

Conductivity

IS 17048

≤ 10 �s/mm

Chlorine and bromine expressed as content of HCL

IS 10810 P - 59

≤ 0.5%

Presence of fluorine

IS 17048

≤ 0.1%