POLY WRAPPED SUBMERSIBLE COPPER WINDING WIRE
Description
We also offer poly wrapped winding wire commonly known as “Submersible Copper Winding Wire”. The copper conductor is wrapped with thin polyester film and Biaxial oriented poly propylene (BOPP) films. A complete quality assurance testing by instruments covering all governing standards is available.
Application
Submersible Winding Wires are used in submersible pumps motors of all sizes for domestic and industrial application.
Size Range
0.50mm- 2.50 mm
Specifications
IS 8783:1995.
Introduction
Submersible winding wires are the type of winding wires having close contact with water or different liquids. In fact many submersible motors are designed in such a way that windings are immersed in the water itself, which works as a cooling media while the pump is in operation.
In early years, submersible winding wires have been developed with PVC insulation, which were having thicker insulations for getting required electrical properties.
Later, with the development of Poly wrapped wires, which has less insulation thickness and better properties. This reduced size of motors to great extent. We are manufacturing and supplying the poly wrapped VR KABLE brand wires to you since long time.
The continuous extrusion process with on line spark tester gives consistent 100 % checked quality of wire. It can give longer lengths as required by customer. This avoids joints in winding and reduces winding process scrap and integrity of the windings. The superior surface properties with extra softness give an excellent ease of slot filling, and shaping.
The sample motors wound and tested for long term tests found excellent operational results.
Applicable Standards: -
NA – Guide lines and requirements taken from IS 8783- Part 4 Section 3
Comparison Test Analysis of POLYSTER & BOPP Wrapped
Sl No |
Test |
Spec Value are Per IS 8783 part 4 |
Poly wrapped POLYSTER & BOPP |
1 |
Surface |
Smooth/ Wrapped |
Wrapped wavy |
2 |
Dimension |
As per Customer Specifications |
OD ranges 0.300 to 0.900 |
3 |
Concentricity |
– |
Fully concentric insulation, due to wrapping |
4 |
Softness of Wire |
Fully Annealing |
Slight harness due to wrapping and shrinking process |
5 |
Volume Resistivity at 27°C(IS 10810 Pt-43), IS 5831 |
1 X 1016 |
1.8 – 2.2 X 1016 |
6 |
Volume Resistivity at 90°C(IS 10810 Pt-43), IS 5831 |
1 X 1013 |
6 5- 7.5 X 1013 |
7 |
High Voltage test after 12 hours immersion in water |
3.0Kv for 1 mints to pass |
Passes Leakage current slight more due to air gap in wrapping |
7.1 |
Shrinkage Test at 150°c for 15 Mints |
4% Max |
2 to 3.5% |
7.2 |
Heat Shock Test |
To pass at 150°C for 1 hrs |
Passes- Layer separation forms at 170°C and HV/Megger mostly fails |
Benefits
- Smooth insulation surface along with super soft annealed copper wire
- Very low co-efficient of friction, easy for slot insertion
- Less springiness, does not require hammering for shaping of coils.
- Longer lengths coils/ Reels possible
- Benefits of extra meter lengths/Kg lesser weight compared to Poly Wrapped wire
- Fixed lengths coils are provided by meter counters. Applications
- Retain the original box packing till actual usage.
- Place the wire coils and wound coils on Rubber sheets to avoid damages.
- Use the provided bubble sheet to place coils – Do not place on corrugate boxes – they have staple pins that can damage the insulations.
- Examine and rectify for any sharp Objects/Sharp corners which can come in wire path during coiling.
- Do not give more force on the coils to fit in slots. Avoid any sort of damages during coil fitting.
- Use proper grade of insulation paper to guide the coils through slots
- Only use smooth tipped wooden strip to push wires in slots
- If required, apply a small quantity of lubricant oil in holding cloth / felt tensioner
- Search for sharp objects on working stations and avoid contact with wound coils motors
- Check the wooden/plastic slot fillers. It should not damage the wires while pushing.
- Ensure proper transit/packaging of wound stator.
All types of single phase, three phase submersible motor pumps. Conductor Dia range 0.40 to 2.60mm and Insulation covering range 0.30 to 1.00mm.
Safety and Precautions considering the fact that the insulation is softer than Poly wrapped wires, certain precautions must be taken during transit, handling usage of M. H. Classic Submersible Winding wires.
POLY WRAPPED SUBMERSIBLE WINDING WIRES OF COPPER
SR. NO. |
Nominal Conductor Diameter |
Max Over all Diameter |
|
Area of Conductor |
Nominal Resistance |
Elongation at Break |
|
|
mm |
mm |
mm |
mm |
per meter at 200C |
Minimum % |
Minimum % |
1 |
0.50 |
1.000 |
0.800 |
0.1964 |
0.0871 |
25 |
28 |
2 |
0.60 |
1.100 |
0.900 |
0.2828 |
0.0605 |
26 |
30 |
3 |
0.70 |
1.200 |
1.000 |
0.3849 |
0.0444 |
28 |
32 |
4 |
0.80 |
1.300 |
1.100 |
0.5027 |
0.0340 |
28 |
32 |
5 |
0.90 |
1.400 |
1.250 |
0.6363 |
0.0269 |
29 |
32 |
6 |
1.00 |
1.500 |
1.350 |
0.7855 |
0.0218 |
30 |
34 |
7 |
1.10 |
1.600 |
1.450 |
0.9505 |
0.0180 |
30 |
34 |
8 |
1.20 |
1.700 |
1.550 |
1.1311 |
0.0151 |
31 |
35 |
9 |
1.30 |
1.800 |
1.650 |
1.3275 |
0.0129 |
32 |
35 |
10 |
1.40 |
2.000 |
1.750 |
1.5396 |
0.0111 |
32 |
35 |
11 |
1.50 |
2.100 |
1.900 |
1.7674 |
0.0097 |
32 |
35 |
12 |
1.60 |
2.200 |
2.000 |
2.0109 |
0.0085 |
32 |
36 |
13 |
1.70 |
2.300 |
2.100 |
2.2701 |
0.0075 |
32 |
36 |
14 |
1.80 |
2.400 |
2.200 |
2.5450 |
0.0067 |
32 |
36 |
15 |
1.90 |
2.500 |
2.300 |
2.8357 |
0.0060 |
32 |
36 |
16 |
2.00 |
2.600 |
2.400 |
3.1416 |
0.0055 |
33 |
37 |
17 |
2.10 |
2.700 |
2.500 |
3.4641 |
0.0049 |
33 |
37 |
18 |
2.20 |
2.800 |
2.600 |
3.8018 |
0.0045 |
33 |
37 |
19 |
2.30 |
3.100 |
2.800 |
4.1553 |
0.0041 |
33 |
37 |
20 |
2.40 |
3.200 |
2.900 |
4.5245 |
0.0038 |
33 |
37 |
21 |
2.50 |
3.300 |
3.000 |
4.9094 |
0.0035 |
33 |
37 |